Status: RESOLVED (January 30, 2026)

Summary

The run failed on main while passing on feature and development branches.

Failure details

The primary error is a socket hang up during a security test in zzz-admin-whitelist-blocking.spec.ts:

Error: apiRequestContext.post: socket hang up at
tests/security-enforcement/zzz-admin-whitelist-blocking.spec.ts:126:21

The test POSTs to the admin reset endpoint, but the test container cannot reach the admin API endpoint. This blocks the emergency reset and fails the test.

Likely cause

The admin backend at http://localhost:2020 is not running or not reachable from the test runner container.

  • Ensure the admin backend is running and accessible from the test runner.
  • Confirm the workflow starts the required service and listens on port 2020.
  • If using Docker Compose, ensure the test container can reach the admin API container (use depends_on and compatible networking).
  • If the endpoint should be served by the app under test, verify environment variables and config expose the admin API on the correct port.

Optional code adjustment

If Playwright must target a non-default admin endpoint, read it from an environment variable such as CHARON_ADMIN_API_URL.

Resolution

Fixed by ensuring proper Docker Compose networking configuration and verifying admin backend service availability before test execution. Tests now properly wait for service readiness.