Complete Phase 4 implementation enabling ACL, WAF, and Rate Limiting
toggle functionality in the Security Dashboard UI.
Backend:
Add 60-second TTL settings cache layer to Cerberus middleware
Trigger async Caddy config reload on security.* setting changes
Query runtime settings in Caddy manager before config generation
Wire SettingsHandler with CaddyManager and Cerberus dependencies
Frontend:
Fix optimistic update logic to preserve mode field for WAF/rate_limit
Replace onChange with onCheckedChange for all Switch components
Add unit tests for mode preservation and rollback behavior
Test Fixes:
Fix CrowdSec startup test assertions (cfg.Enabled is global Cerberus flag)
Fix security service test UUID uniqueness for UNIQUE constraint
Add .first() to toast locator in wait-helpers.ts for multiple toasts
Documentation:
Add Security Dashboard Toggles section to features.md
Mark phase4_security_toggles_spec.md as IMPLEMENTED
Add E2E coverage mode (Docker vs Vite) documentation
Enables 8 previously skipped E2E tests in security-dashboard.spec.ts
and rate-limiting.spec.ts.
- Implemented `useManualChallenge`, `useChallengePoll`, and `useManualChallengeMutations` hooks for managing manual DNS challenges.
- Created tests for the `useManualChallenge` hooks to ensure correct fetching and mutation behavior.
- Added `ManualDNSChallenge` component for displaying challenge details and actions.
- Developed end-to-end tests for the Manual DNS Provider feature, covering provider selection, challenge UI, and accessibility compliance.
- Included error handling tests for verification failures and network errors.
- Added QA summary report for CrowdSec toggle fix validation, detailing test results, code quality audit, and recommendations for deployment.
- Updated existing QA report to reflect the new toggle fix validation status and testing cycle.
- Enhanced security documentation to explain the persistence of CrowdSec across container restarts and troubleshooting steps for common issues.
- Expanded troubleshooting guide to address scenarios where CrowdSec does not start after a container restart, including diagnosis and solutions.
- Make Stop() idempotent: return nil instead of error when PID file missing
- Add startup reconciliation: auto-start CrowdSec if DB says enabled
- Ensure log file exists for LogWatcher to prevent disconnection
Fixes:
- "Failed to stop CrowdSec: 500 error" when toggling off
- CrowdSec showing "not running" despite being enabled in settings
- Live logs showing disconnected after container restart